Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Year range
1.
Arq. ciênc. vet. zool. UNIPAR ; 8(2): 117-124, jul.-dez. 2005. ilus, tab
Article in Portuguese | LILACS | ID: lil-444812

ABSTRACT

RESUMO: Os avanços tecnológicos dos meios diagnósticos benefi ciam a Medicina Veterinária. Para que novas tecnologias sejam utilizadas, são necessárias informações sobre os padrões normais para cada tipo de exame, o que possibilita sua utilização na rotina e destinação, adequadamente, a cada paciente. A fl uxometria ultra-sonográfi ca está começando a ser utilizada em Medicina Veterinária com fi nalidades e propósitos diversos. Para destiná-la a um fi m específi co, o presente trabalho teve por objetivo verifi car a fl uxometria ultra-sonográfi ca da artéria oftálmica externa em gatos. Para tanto, foram utilizados 20 gatos sem raça defi nida, 12 machos e 8 fêmeas, com massa corporal entre 2,0 e 4,0 kg, hígidos, provenientes da Sociedade de Amparo aos Animais de Umuarama ­ PR. Os animais foram anestesiados pela associação de tiletamina e zolazepam, administrada por via intramuscular, na dose de 6,0 mg/kg. A fl uxometria da artéria oftálmica externa foi obtida por meio do equipamento de ultra-sonografi a Toshiba Powervision ATL-HDI 3500, dotado de "eco-doppler", com transdutor setorial de 6,0 MHz, aplicado diretamente sobre a córnea. Cada olho teve o fl uxo de sua artéria aferido pelo programa do próprio aparelho, sendo tomadas três amostras. O índice de resistência vascular foi calculado com base nos valores do fl uxo sistólico e diastólico médio de cada vaso. Os valores foram tabulados e teste t de Student foi aplicado para verifi cação de diferenças entre as médias. No olho direito, obteve-se velocidade de fl uxo de 41,3 ± 14,28 cm/seg para a artéria oftálmica externa, em sístole, e 23,95 ± 11,46 cm/seg, em diástole. No olho esquerdo, 42,75 ± 12,64 cm/seg, em sístole, e 25,45 ± 9,61 cm/seg, em diástole. Não houve diferença signifi cativa entre os olhos. O índice de resistência vascular calculado foi de 0,4175 para a artéria oftálmica externa, no olho direito, e 0,4015 no olho esquerdo, sem diferença signifi cativa entre os olhos. Os resultados apontam para um mecanismo intrínseco de controle do fl uxo, controlado por fatores locais na artéria oftálmica externa, e os valores do índice de resistência denotam uma artéria de baixo fluxo


ABSTRACT: Veterinary medicine is benefi ted by technological advances in diagnosis. In order that new technologies may be used, information about normal standards for each type of examination is necessary, so that they may be used routinely and adequately prescribed for each patient. The Doppler ultrasound is beginning to be used in veterinary medicine for diverse purposes. The objective of this study is to verify the Doppler ultrasound fl ow of the external ophthalmic artery in cats. There were used 20 mixed breed cats, being 12 males and eight females, weighing from 2.0 to 4.0 kg, supplied by the Amparo aos Animais Society, an animal shelter from the city of Umuarama, State of Paraná, Brazil. The animals were anesthetized with 6.0 mg/kg of the association tiletamine plus zolazepam, given by intramuscular route. The fl ow of the external ophthalmic artery was measured through the ultrasound equipment Toshiba Powervision ATL-HDI 3500, with an echo-Doppler and a sectorial transducer of 6.0 MHz, directly applied to the cornea. Each eye had the artery fl ow surveyed by the equipment's own software, in which three samples have been taken. The vascular resistance index was calculated based on the mean values of systolic and diastolic fl ow of each vessel. The values were tabulated and Student t test was applied to verify differences between the averages. In the right eye, the value for the external ophthalmic artery fl ow was 41.30 ± 14.28 cm/sec, in systole, and 23.95 ± 11.46 cm/seg, in diastole. For the left eye, the value was 42.75 ± 12.64 cm/sec, in systole, and 25.45 ± 9.61 cm/sec, in diastole. There were no signifi cant differences between the eyes. The calculated index of vascular resistance was 0.4175 ± 0.0774 for the external ophthalmic artery in the right eye, and 0.4015 ± 0.0719 for the left eye, without signifi cant difference between the eyes. The results point out to an intrinsic mechanism of fl ow control, controlled by local factors in the external ophthalmic artery, and the resistance index values denote a low fl ow artery


RESUMEN: La medicina veterinaria se benefi cia de los adelantos tecnológicos en diagnóstico. El conocimiento de los padrones normales para cada tipo y examen es fundamental para que se puedan usar nuevas tecnologías, posibilitando su empleo rutinario yla indicación adecuada a cada paciente. El objetivo de este estudio fue verifi car la fl ujometría por ultrasonido de la arteria oftálmica externa en gatos. Se emplearon 20 gatos sin raza defi nida, 12 machos y ocho hembras, que provinieron de la Sociedad de Amparo a los Animales de la ciudad de Umuarama, Estado de Paraná, Brasil. Los animales fueron anestesiados con 6.0 mg/kg de la asociación de tiletamina y zolazepam, ministrados por vía intramuscular. El fl ujo de la arteria oftálmica externa fue mensurado por medio del equipo del ultrasonido Toshiba Powervision ATL-HDI 3500, con un eco-doppler y un transductor sectorial de 6.0 MHz, directamenteaplicado a la córnea. Cada ojo tenía el fl ujo de la arteria evaluado por el propio programa del equipo, tomándose tres muestras. El índice de resistencia vascular se calculó basado en los valores promedios de fl ujo sistólico y diastólico de cada vaso. Los valores fueron tabulados y se aplicó el teste t de Student para verifi car diferencias entre los promedios. En el ojo derecho, el valor para el fl ujo de la arteria oftálmica externa fue 41,30 ± 14.28 cm/sec, en sístole, y 23,95 ± 11,46 cm/seg, en diástole. Para el ojo izquierdo, el valor fue 42,75 ± 12,64 cm/seg, en sístole, y 25,45 ± 9,61 cm/sec, en diastole. No se observó diferencia signifi cante entre los ojos. El índice calculado de resistencia vascular fue 0,4175 ± 0,0774 para la arteria oftálmica externa en el ojo derecho, y 0.4015 ± 0.0719 para el ojo izquierdo, sin diferencia signifi cante entre los ojos. Los resultados apuntan para un mecanismo intrínseco de control de fl ujo, controlado por factores locales en la arteria oftálmica externa, y los valores del índice de resistencia denotan una arteria de bajo fl ujo


Subject(s)
Animals , Ophthalmic Artery/ultrastructure , Laser-Doppler Flowmetry/methods , Laser-Doppler Flowmetry/veterinary , Cats
SELECTION OF CITATIONS
SEARCH DETAIL